Mon - Sun : 09:00 - 17:00
Our process completes each batch in just 20 minutes, delivering a swift and energy-efficient production cycle. Traditional methods require at least 2 hours for heating and mixing, making our approach significantly faster.
Our system meets the highest standards, boasting certifications like VDA, ISO 9001, ISO 13485, and ISO 14001, ensuring the utmost quality and compliance in our production process.
Mixing urea with water triggers an endothermic reaction, reducing the temperature. Our system requires just 15 kW of energy to dissolve urea, compared to 75 kW in traditional systems, leading to lower production costs.
We provide the A.TR document, ensuring that you won’t pay taxes at the border. This document simplifies the process and helps you save money on cross-border transactions.
Our automated system dynamically adjusts the urea-water mix in real-time, eliminating the need for manual intervention. This innovation ensures consistent quality and reduces energy waste.
Only one person is needed to manage the production process. They simply load the urea into the hopper and monitor the system for three hours, after which a quality check is performed.
The SCR system injects AdBlue® directly into the exhaust stream. When it enters the catalytic converter, it reacts with nitrous oxides from the combusted diesel – producing non-hazardous, naturally occurring nitrogen and water
Due to its outstanding purity, AdBlue® by Our System neither damages the SCR system nor reduces3 its lifespan.
AdBlue® Specifications During VDA Standards | ||
---|---|---|
APPEARANCE | CLEAR LIQUID | DN 8-53 |
UREA CONTENT | 32.5 ± 0.7 | ISO 22241-2 |
ALKALINITY AS NH3 | 0.2 % MAX | ISO 22241-2 |
REFRACTIVE INDEX AT 20°C | 1.3814 – 1.3843 | ISO 22241-2 |
BIURET | 0.3 WT% MAX | ISO 22241-2 |
ALDEHYDES | 5.0 MG/KG MAX | ISO 22241-2 |
INSOLUBLE MATTER | 20 MG/KG MAX | ISO 22241-2 |
PHOSPHATE (PO4) | 0.5 MG/KG MAX | ISO 22241-2 |
CALCIUM | 0.5 MG/KG MAX | ISO 22241-2 |
IRON | 0.5 MG/KG MAX | ISO 22241-2 |
COPPER | 0.2 MG/KG MAX | ISO 22241-2 |
ZINC | 0.2 MG/KG MAX | ISO 22241-2 |
CHROMIUM | 0.2 MG/KG MAX | ISO 22241-2 |
NICKEL | 0.2 MG/KG MAX | ISO 22241-2 |
SODIUM | 0.5 MG/KG MAX | ISO 22241-2 |
ALUMINIUM | 0.5 MG/KG MAX | ISO 22241-2 |
MAGNESIUM | 0.5 MG/KG MAX | ISO 22241-2 |
POTASSIUM | 0.5 MG/KG MAX | ISO 22241-2 |
IR | YES | IDENTICAL TO REFERENCES |
VDA Certificate
CAPACITY: 2 m3/h
ELECTRIC: 380 V – 10 kW
NEEDED AREA: 300 m2
CAPACITY: 2 m3/h
ELECTRIC: 380 V – 10 kW
NEEDED AREA: 300 m2
CAPACITY: 2 m3/h
ELECTRIC: 380 V – 10 kW
NEEDED AREA: 300 m2
CAPACITY: 2 m3/h
ELECTRIC: 380 V – 10 kW
NEEDED AREA: 300 m2
Characteristics | Unit | Drinking Water (ISO: 10500) | Deionized Water (ISO 22241) |
---|---|---|---|
Aluminum | mg/l Max | 0.03 | 0.5 |
Calcium | mg/l Max | 75 | 0.5 |
Iron | mg/l Max | 0.3 | 0.5 |
Magnesium | mg/l Max | 30 | 0.5 |
Conductivity | μS/m | 5,000-50,000 | 5.5 |
DEF by Our System
SCR system after 40,000 km
using DEF such as AdBlue® by Our System
DEF by traditional systems
SCR system after 40,000 km
using low-quality traditional systems